Master 2021 Latest The Questions Cisco and NetApp FlexPod and Pass NS0-176 Real Exam!
Penetration testers simulate NS0-176 exam PDF
NEW QUESTION 75
You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails.
What is a cause for this failure?
- A. The cluster LIFs on each node cannot communicate with the cluster LIFs on each node in the peer cluster.
- B. The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster.
- C. The cluster management LIF for the cluster cannot communicate with the cluster management LIF for the peer cluster.
- D. The node management LIF on each node cannot communicate with the node management LIF on each node in the peer cluster.
Answer: B
NEW QUESTION 76
Where are log files located on a NetApp node?
- A. /etc/mlog/
- B. /log/core/
- C. /mroot/etc/log/mlog/
- D. /mroot/etc/crash/
- E. /letc/log/crash
Answer: C
NEW QUESTION 77
An administrator has a FlexPod solution configured for Microsoft Hyper-V 2012 R2. The hypervisor will be using CIFS shares for Cluster Shared Volume (CSV) datastores. A storage virtual machine (SVM) is configured, and a CIFS share is created for use.
When attempting to add the CSV datastore to the CIFS share, an error occurs and the datastore is not created.
Which three steps should the administrator perform to solve the problem? (Choose three.)
- A. Configure the export policy with the Hyper-V host IP address.
- B. Configure the ~-smb3-enabled~ parameter on the SVM.
- C. Create multiple LIFs for CIFS Hyper-V traffic to enable ALUA.
- D. Enable the "Continuous Availability" setting on the CIFS share.
- E. Configure the "Enable Oplocks" setting on the CIFS share.
Answer: A,B,E
NEW QUESTION 78
When configuring a volume to contain a LUN, which administrative tool automatically applies NetApp recommendations?
- A. Microsoft SystemCenter
- B. Data ONTAP command-line interface
- C. VMware vSphere
- D. OnCommand System Manager
Answer: D
NEW QUESTION 79
You are asked to increase read performance for a single aggregate; however, there are no PCI-e slots available in the NetApp cluster nodes.
In this scenario, which feature meets these requirements?
- A. Flash Cache
- B. Advanced Drive Partitioning
- C. Thin Provisioning
- D. Flash pool
Answer: D
NEW QUESTION 80
VMware ESXi 6 supports which three storage protocols? (Choose three.)
- A. NFS
- B. FCP
- C. SMB
- D. CIFS
- E. iSCSI
Answer: B,D,E
NEW QUESTION 81
A Cisco UCS system is operating in FC End-Host Mode. The fabric Interconnects are uplinked into Nexus 5672UP switches using native FC. The service profiles are unable to boot from SAN using FC.
When executing the show flogi database command on the Nexus switches, only the Fabric Interconnect port WWNs are visible. No service profile WWNs are shown.
What caused this issue?
- A. The zoning on the Nexus switches is incorrect.
- B. The Nexus switches do not have NPIV enabled.
- C. The Nexus switches do not have NPV enabled.
- D. The Nexus must be configured for FCoE instead of native Fibre Channel.
Answer: B
NEW QUESTION 82
Which endpoint's firmware can be directly upgraded (without the use of a Service Profile) using UCS Manager?
- A. CIMC
- B. RAID Controller
- C. HBA
- D. BIOS
Answer: A,D
NEW QUESTION 83
A disaster occurred and both Cisco UCS Fabric Interconnects must be replaced. You must restore the system from a "full state" backup.
Which two steps will accomplish this task? (Choose two.)
- A. Restore the "full state" backup using the UCS Manager "import configuration" wizard.
- B. Restore the "full state" backup through the primary Fabric Interconnect's initial system setup wizard.
- C. Upgrade the new Fabric Interconnects to the same version of firmware as the previous Fabric Interconnects.
- D. Remove the current firmware from the new Fabric Interconnects.
Answer: A,C
NEW QUESTION 84
What aggregate containing the root volume is created during the Clustered Data ONTAP setup process?
- A. 16-bit
- B. 64-bit
- C. 32-bit
- D. 8-bit
Answer: B
NEW QUESTION 85
What is the correct flow control setting for the intercluster ports on a NetApp cluster?
to 50% cashback.
- A. switched cluster = none switchless cluster = none
- B. switched cluster = set to match the setting on switch port switchless cluster = none
- C. switched cluster = none switchless cluster = full
- D. switched cluster = full switchless cluster = none
Answer: B
NEW QUESTION 86
Exhibit:
Your customer has a FlexPod VMware solution deployed with NFS datastores. As shown in the exhibit, the links between the Fabric Interconnects and storage controllers are single-mode interface groups with autorevert set to true, hosting a single access LIF. NFS I/O is currently going through fabric A to ST-A. The customer wants to use both fabrics for NFS I/O.
In this scenario, what will accomplish this task?
- A. Configure VMware hosts to utilize an NFS LIF on ST-B that is connected to fabric A.
- B. Configure VMware hosts to use a new datastore with an NFS LIF on ST-B connected to fabric B.
- C. Add two physical links between SW-A and SW-B.
- D. Migrate the existing LIF that is used for NFS I/O on ST-A to its HA partner ST-B.
Answer: B
NEW QUESTION 87
When creating local user, which two are valid user names? (Choose two)
- A. somebody
- B. daemon
- C. root
- D. 0
- E. best_user
- F. 1greatuser
Answer: A,E
NEW QUESTION 88
Which two are two possible features of the 'Call Home' feature in UCS Manager?
- A. Ability to proactively open a case with the Cisco TAC with the 'Smart Call Home' feature
- B. Generates a syslog event
- C. Generates a text message to configured cell phone numbers
- D. Allows UCS to proactively pull down new software updates from Cisco
- E. Generates emails to predefined email addresses when a problem is detected
Answer: A,E
NEW QUESTION 89
An administrator has a FlexPod solution and is using OnCommand Unified Manager and OnCommand Performance Manager to monitor the FlexPod environment. Full integration has previously been configured between the two OnCommand virtual appliances; however, new performance issues are not being seen in the OnCommand Unified Manager dashboard.
In this scenario, which two settings should the administrator verify? (Choose two.)
- A. Ensure that the Event Publisher user credentials are entered correctly on the OnCommand Performance Manager appliance.
- B. Ensure that network connectivity exists between the two virtual appliances.
- C. Ensure that OnCommand Performance Manager is licensed for use with OnCommand Unified Manager.
- D. Ensure that the NetApp cluster is configured to forward SNMP data to OnCommand Performance Manager.
Answer: A,C
NEW QUESTION 90
You have a NetApp clustered Data ONTAP storage system and vSphere 6 cluster. You discover that VMware VAAI for NFS is not showing as enabled on one of the five ESXi hosts in your vSphere cluster.
In this scenario, what must you do to enable VAAI for NFS on that ESXi host?
- A. Set the DataMover. HardwareAcceleratedInit advanced setting to 0 on the ESXi host.
- B. Install the NetApp NFS Plug-in for VMware VAAI on the ESXi host.
- C. Enable NFSv3 on the storage system.
- D. Enable VMware vStorage for NFS on the NetApp SVM.
Answer: C
NEW QUESTION 91
Under which tab in UCS Manager would you create a boot policy?
- A. SAN
- B. Servers
- C. Equipment
- D. LAN
Answer: B
NEW QUESTION 92
When configuring a FlexPod environment for iSCSI boot with Cisco UCS, which item should be preconfigured?
- A. WWPN Pools.
- B. All zoning should be configured.
- C. Zonesets should be created.
- D. IQN and IP address of target.
Answer: D
NEW QUESTION 93
NetApp recommends that your SSL key length be?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION 94
On a NetApp clustered Data ONTAP cluster, a volume named datastorel resides on an aggregate named node1 aggr1 and is mounted into the namespace at the junction path /esx cluster1/ds1.
A VMware virtual machine file named myhost.vmdk is at the root of the volume datastorel. A volume move operation relocates the datastorel volume to an aggregate named node3 aggr1.
In this scenario, what is the full path to the file myhost.vmdk after the volume move is complete?
- A. /esx_cluster1/ds1/myhost.vmdk
- B. /esx_cluster1/datastore1/myhost.vmdk
- C. node3_aggr3/esx_cluster1/ds1/myhost.vmdk
- D. /vo1/esx_cluster1/ds1/myhost.vmdk
Answer: A
NEW QUESTION 95
......
Penetration testers simulate NS0-176 exam: https://www.itpass4sure.com/NS0-176-practice-exam.html

