[Jan 07, 2022] Lesson Brilliant PDF for the NS0-176 Tests Free Updated Today [Q80-Q99]

Share

[Jan 07, 2022] Lesson Brilliant PDF for the NS0-176 Tests Free Updated Today

Get New 2022 Valid Practice Cisco and NetApp FlexPod NS0-176 Q&A - Testing Engine


NetApp NS0-176 Exam Certification Details:

Exam Price$150 USD
Passing Score68%
Number of Questions60
Exam RegistrationPEARSON VUE
Duration60 minutes
Exam CodeNS0-176 FlexPod
Sample QuestionsNetApp NS0-176 Sample Questions
Exam NameCisco and NetApp FlexPod Implementation and Administration

 

NEW QUESTION 80
You are asked to verify your MPIO settings for your ONTAP FlexPod solution. You are using VMware ESXi 6 and FCP as the storage protocol.
In this scenario, which MPIO setting would you use on the ESXi host?

  • A. fixed path with array preference
  • B. fixed path
  • C. round robin
  • D. most recently used

Answer: C

 

NEW QUESTION 81
You run NetApp ConfigAdvisor against you FAS8060A storage system. The report states that the flow control settings for ports e0a on each node are incorrect.
Which set of commands will correct this problem?

  • A. network port modify -node netapp-01 -port e0a -flowcontrol-admin none network port modify -node netapp-02 -port e0a -flowcontrol-admin none
  • B. network interface modify- node netapp-01 port e0a-flowcontrol-admin full network interface modify- node netapp-02 port e0a-flowcontrol-admin full
  • C. network interface modify- node netapp-01 -port e0a -flowcontrol -admin none network interface modify -node netapp-02 -port e0a -flowcontrol - admin none
  • D. network port modify- node netapp-01 port e0a-flowcontrol-admin full network port modify- node netapp-02 port e0a-flowcontrol-admin full

Answer: A

 

NEW QUESTION 82
Which two are correct about VSAN configuration within UCS Manager? (Choose two)

  • A. In addition to SAN tab, VSANs can be configured under UCSM Server tab as well.
  • B. VSAN can be configured as fabric interconnect specific.
  • C. We can delete VSAN 1.
  • D. VSAN can be configured as a global parameter.
  • E. VSAN IDs 3840-4079 are not available regardless of the Fabric Interconnect mode.
  • F. VSAN ID and FCoE VLAN ID have to match.

Answer: B,C

 

NEW QUESTION 83
Which management tool is used to configure and monitor centralized policies for multiple Cisco UCS domains?

  • A. UCS Director
  • B. UCS Performance Manager
  • C. UCS Central
  • D. UCS Manager

Answer: C

 

NEW QUESTION 84
For a 'boot from SAN' configuration, which two features must be enabled? (Choose two)

  • A. FCSP
  • B. FCOE
  • C. UDLD
  • D. VPC
  • E. FC
  • F. NPIV

Answer: B,F

 

NEW QUESTION 85
What management solution can provision all three components of a FlexPod (NetApp storage, Cisco UCS compute and Cisco Nexus network)?

  • A. NetApp OnCommand Insight
  • B. Cisco UCS Director
  • C. Cisco UCS Central
  • D. Cisco FlexPod Manager
  • E. NetApp FlexPod Manager

Answer: B

 

NEW QUESTION 86
Exhibit:

You are configuring iSCSI boot from SAN on your UCS blades.
Referring to the exhibit, how many paths will there be to the Boot LUN?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

 

NEW QUESTION 87
You are installing two NetApp FAS8080 EX controllers.
Which two ports would you use for HA connectivity? (Choose two.)

  • A. e0e
  • B. ib0b
  • C. eof
  • D. ib0a

Answer: B,D

 

NEW QUESTION 88
Exhibit:

An iSCSI SAN boot is not working for a new Cisoc UCS service profile. The new vNIC template was created using the settings shown in the exhibit.
What should you do to make iSCSI SAN boot work?

  • A. Set the iSCSI-A-VLAN as the "Native VLAN".
  • B. Specify a QoS policy.
  • C. Change the vNIC template to type "Initial Template".
  • D. Change the MAC pool to "<not set>".

Answer: B

 

NEW QUESTION 89
Refer to the exhibit.

Which is correct for configuring FCoE?

  • A. vlan 33fcoe vsan 43int po11switchport trunk allowed vlan add 33int vfc11bind interface po11switchport trunk allowed vsan 43vsan databasevsan 43 interface vfc11
  • B. vlan 33fcoe vsan 43int po21switchport trunk allowed vsan add 43int vfc11bind interface po21vsan databasevsan 43 interface vfc 11
  • C. fcoe vsan 43int po11switchport trunk allowed vsan add 43vsan databasevsan 43
  • D. fcoe vsan 43int po21switchport trunk allowed vsan add 43vsan databasevsan 43
  • E. fcoe vlan 33int po11switchport trunk allowed vlan add 33vsan databasevsan 33

Answer: A

 

NEW QUESTION 90
In which two locations is the VSAN ID configured in a FlexPod solution? (Choose two.)

  • A. Nexus switches
  • B. hypervisor adapter
  • C. Storage Virtual Machine
  • D. UCS Manager

Answer: A,D

 

NEW QUESTION 91
VMware ESXi 6 supports which three storage protocols? (Choose three.)

  • A. FCP
  • B. NFS
  • C. iSCSI
  • D. CIFS
  • E. SMB

Answer: A,C,D

 

NEW QUESTION 92
You are installing a FlexPod Express solution with a NetApp AFF A250 at a customer's remote site.
In this scenario, which two devices are required to provide an NFS v3 datastore? (Choose two.)

  • A. NetApp BES-53248 Switches
  • B. Cisco UCS 6324 Fabric Interconnects
  • C. Cisco UCS 6454 Fabric Interconnects
  • D. Cisco Nexus 3000 Switches

Answer: B,D

 

NEW QUESTION 93
To support Storage Virtual Machines, which type of unique login account must be created?

  • A. vsadmin, for the cluster
  • B. admin, for the cluster
  • C. admin, for each Storage Virtual Machine
  • D. vsadmin, for each Storage Virtual Machine

Answer: D

 

NEW QUESTION 94
Which aggregates should be disabled for data aggregates?

  • A. SnapMirror copies
  • B. iSCSI
  • C. Snapshot copies
  • D. FCP

Answer: C

 

NEW QUESTION 95
You currently have a FlexPod Datacenter solution, and you are merging with another company. That company's environment currently has a mix of different Cisco servers. You want to add as many of those servers to your FlexPod solution as possible.
In this scenario, which two Cisco servers are supported in a FlexPod environment? (Choose two.)

  • A. S3260 M5
  • B. B200 M5
  • C. HX240c Edge M5
  • D. C480 ML M5

Answer: B,D

 

NEW QUESTION 96
Your company is looking for a small remote office infrastructure to deploy to your 30 remote sites. You are asked to write deployment procedures for each site. Your goal is to have each site deployed in less than a day.
Which tool will help you accomplish your goal?

  • A. OnCommand Insight
  • B. UCS Director
  • C. OnCommand System Manager
  • D. UCS Manager

Answer: B

 

NEW QUESTION 97
You are attempting to establish a cluster peer relationship between two NetApp clusters, but the peering process fails.
What is a cause for this failure?

  • A. The cluster management LIF for the cluster cannot communicate with the cluster management LIF for the peer cluster.
  • B. The node management LIF on each node cannot communicate with the node management LIF on each node in the peer cluster.
  • C. The intercluster LIF on each node cannot communicate with the intercluster LIF on each node in the peer cluster.
  • D. The cluster LIFs on each node cannot communicate with the cluster LIFs on each node in the peer cluster.

Answer: C

 

NEW QUESTION 98
There are 2 chassis tied to a pair of Fabric Interconnects.
First chassis, chassis-1, has 1 link between single IOM and Fabric Module. Second chassis, chassis-4, has 4 links between single IOM and Fabric Module. Chassis discovery policy is set for 2 links.
Which statement is true?

  • A. Chassis-1 will not be added to UCS Domain. Chassis-4 will be added to UCS domain with all 4 links operating after chassis acknowledgement.
  • B. Both chassis will be added to UCS Domain utilizing all links. No additional steps needed.
  • C. Both chassis will be added to UCS Domain utilizing all links only after performing chassis acknowledgment.
  • D. Chassis-1 will not be added to UCS Domain. Chassis-4 will be added to UCS domain with all 4 links operating and no additional steps needed.

Answer: A

 

NEW QUESTION 99
......


NetApp NS0-176 Exam Topics:

SectionObjectives
FlexPod Administration- Demonstrate knowledge of how to administer FlexPod solutions according to FlexPod best practices
- Describe FlexPod management applications
- Demonstrate knowledge of how to install and upgrade the FlexPod solution
Information Gathering for FlexPod Solutions- Describe the main FlexPod components
FlexPod Design- Describe the storage components supported in FlexPod
- Describe the networking components supported in FlexPod
- Describe the compute components supported in FlexPod
FlexPod Troubleshooting- Demonstrate how to perform FlexPod troubleshooting
FlexPod Configuration- Describe how to install and configure the FlexPod components
- Describe how to configure neworks in a UCS solution
- Describe how to configure SAN boot in a FlexPod solution
- Describe knowledge of how to configure a service profile
- Demonstrate knowledge of how to configure storage in a FlexPod solution
- Demonstrate knowledge of how to configure Cisco Nexus switches

 

NS0-176 Dumps PDF - 100% Passing Guarantee: https://www.itpass4sure.com/NS0-176-practice-exam.html